Electroporation electrodes are for use in the electroporation (opening pores in cell membranes with a pulse of electricity to introduce DNA in bacteria or other cells) of adherent cells in vivo or in utero. These electrodes can be used for a variety of applications, including in utero transfection, transdermal drug delivery, and electroporation therapy. Electrode assemblies are designed to produce homogeneous fields of electricity, and they are easy to clean and sterilize.

Electroporation electrodes are for use in the electroporation (opening pores in cell membranes with a pulse of electricity to introduce DNA in bacteria or other cells) of adherent cells in vivo or in utero. These electrodes can be used for a variety of applications, including in utero transfection, transdermal drug delivery, and electroporation therapy. Electrode assemblies are designed to produce homogeneous fields of electricity, and they are easy to clean and sterilize.


18  výsledků nalezeno

SearchResultCount:"18"

Sort Results

Zobrazit seznam Rychlý náhled (novinka)

Ohodnoťte výsledky hledání

Katalogové číslo: (732-0025)
Dodavatel: BTX
Popis: The Petri Pulser™ electrode is a reusable electroporation applicator designed to fit into each single well of a 6-well plate or an individual 35 mm diameter Petri dish. It is suitable for the electroporation of adherent cells in situ or as an alternative to cuvette electroporation for larger cell suspensions volumes.
Měrná jednotka: 1 * 1 KS


Dodavatel: BTX
Popis: This tissue chamber is specifically designed to handle ex-vivo tissue samples that are either larger than normal or have a unique shape making it difficult to transfect using other standard electrodes. This is an efficient method to deliver genes and drugs to a wide range of tissue types including cornea, muscle and skin.

Nové řešení transparentnosti pro evropské zákazníky

Všimli jste si naší nově zlepšené viditelnosti rozmístění zásob u pokladny?

Zjistěte více

Zlepšení rozmístění zásob

Dodavatel: BTX
Popis: These reusable oocyte Petri electrodes are ideal for electroporation of oocytes, embryos, or other cell types in small volumes.

Dodavatel: BTX
Popis: Genepaddles are non invasive, paddle-style, reusable electrodes designed for <i>in vivo</i> and <i>in vitro</i> applications, such as gene delivery (IVEGD) in mouse embryos. The electrodes are placed anterior and posterior to the embryo following injection of the molecule of interest, and an electroporation pulse is delivered.

Katalogové číslo: (732-0000)
Dodavatel: BTX
Popis: This petri dish electrode is designed to be used with a 100 mm petri dish that functions as the electroporation chamber. The electrode is used to electroporate adherent cells or tissue grown in a petri dish.
Měrná jednotka: 1 * 1 KS


Dodavatel: BTX
Popis: 2-Needle Array™ electrodes are needle-style electrodes specifically designed for <i>in vivo</i> drug or gene delivery applications. The electrode consists of a reusable 2-Needle Array™ handle and sterile, disposable, 2-needle arrays.

Dodavatel: BTX
Popis: Calliper electrodes are reusable, calliper-style electrodes for a variety of <i>in vivo</i> applications such as drug or gene delivery. Calliper electrodes consists of a calliper and a pair of plate electrodes.

Dodavatel: BTX
Popis: Tweezertrodes™ are reusable, tweezer style electrodes for<i> in vivo</i> drug or gene delivery applications.

Katalogové číslo: (700-4812)
Dodavatel: BTX
Popis: This flat electrode can be used for both electroporation and electro cell fusion. It generates either a divergent or homogeneous field depending on the orientation of the grooved electrodes.
Měrná jednotka: 1 * 1 KS


Katalogové číslo: (700-4804)
Dodavatel: BTX
Popis: The BTX Meander Fusion Chamber is a novel microslide design which is specifically used for electro cell fusion. The chamber generates a divergent field and is used for fusion of mammalian cells, plant, yeast, fungi and microorganisms.
Měrná jednotka: 1 * 4 KS


Dodavatel: BTX
Popis: Reusable plate electrode designed to directly electroporate adherent cells or electroporate cultured cell monolayers on filters. The Adherent Cell electrode is a reusable electroporation applicator designed to fit into each single well of a 24-well or 12-well plate.

Dodavatel: BTX
Popis: Genetrodes™ are paired, reusable, needle style electrodes that are ideal for <i>in vivo</i> and <i>in ovo</i> electroporation applications, including drug and gene delivery.

Dodavatel: BTX
Popis: This electrode is designed for delicate and/or difficult tissue transfection. Ex vivo electropoartion is an efficient, effective method to introduce genes, drugs or any number of molecules into a tissue. Sandwich configuration ensures a homogeneous field of energy for optimum transfection.

Dodavatel: BTX
Popis: Tweezertrodes™ are reusable, tweezer style electrodes for in vivo, and in utero drug or gene delivery. Tweezertrodes™ consist of a standard 12 cm tweezer that has been modified with stainless steel or platinum circular electrodes at the tip. The gap between the electrode disks may be adjusted from under 1 mm to over 2 cm.

Katalogové číslo: (BTXI45-0510)
Dodavatel: BTX
Popis: This needle style platinum electrode is specifically designed for in vivo applications on the most fragile of tissue types, such as brain tissue. The ultra thin electrode enables pinpoint transfection for greater ease and efficiency in fragile or in accessible tissue.
Měrná jednotka: 1 * 1 KIT


Dodavatel: BTX
Popis: Microslides have been used for embryo manipulation and cell or protoplast fusion. The Microslide fits on the microscope allowing observation of the alignment and fusion process.

Cena na vyžádání
Omezené množství produktu na skladě. Zboží může být k dispozici v jiném skladě poblíž vašeho sídla. Přesvědčte se, že jste přihlášení na stránky, abyste mohli vidět dostupné položky na skladě. Pokud je stále zobrazeno call a potřebujete asistenci, volejte na číslo 321 570 321.
Omezené množství produktu na skladě. Zboží může být k dispozici v jiném skladě poblíž vašeho sídla. Přesvědčte se, že jste přihlášení na stránky, abyste mohli vidět dostupné položky na skladě. Pokud je stále zobrazeno call a potřebujete asistenci, volejte na číslo 321 570 321.
Daná chemikálie je regulována dle platné legislativy a bude vyžadováno vyplnění formuláře. Jeho včasným vyplněním uspíšíte dodání produktu.
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
Tento produkt je zablokován vaší organizací. Kontaktujte své nákupní oddělení pro více informací.
Původní produkt již není k dispozici. Zobrazen je náhradní produkt.
Tento produkt již není k dispozici. Podobné produkty můžete vyhledat pomocí VWR katalogových čísel nebo čísel dodavatele uvedených výše. Pokud potřebujete další asistenci, zavolejte na telefonní číslo zákaznického servisu VWR 321 570 321.
1 - 16 of 18
no targeter for Bottom