Tisk…

Typ výsledku

Hledali jste: Inhibitor removal resin

100  výsledků nalezeno

~~xTIP4-brochure~~

FlexFit® Lower insertion force to make a secure seal StarStop™ Eliminates high ejection forces No Positive Stop Higher ejection forces No FlexFit® Requires higher forces to seal CompetitorBiotix Biotix X-Resin Non-Low Retention Tips Perfect Ergono...

MK-SF-0002_REV01_Ultraplex_qScript_XLT1step_0918.indd

MK-SF-0002_REV01_Ultraplex_qScript_XLT1step_0918.indd Reverse Transcription For more info visit: www.quantabio.com The RT Hot Start functionality of Ultraplex improves low-copy RT-qPCR performance and enables convenient room temperature reaction s...

MK-SF-0002_REV01_Ultraplex_qScript_XLT1step_0918.indd

MK-SF-0002_REV01_Ultraplex_qScript_XLT1step_0918.indd Reverse Transcription For more info visit: www.quantabio.com The RT Hot Start functionality of Ultraplex improves low-copy RT-qPCR performance and enables convenient room temperature reaction s...

Biotium NucView-Flyer

Live Cell Apoptosis Assays NucView® fluorogenic caspase substrates for real-time apoptosis detection in live cells NucView® caspase-3 substrates are novel fluorescent probes that allow real-time detection of caspase-3/7 activity in intact cells. T...

Biotium NucView-Flyer

Live Cell Apoptosis Assays NucView® fluorogenic caspase substrates for real-time apoptosis detection in live cells NucView® caspase-3 substrates are novel fluorescent probes that allow real-time detection of caspase-3/7 activity in intact cells. T...

MK-SF-0025_REV01_PerfeCTa_Multiplex_qPCR_0918.indd

MK-SF-0025_REV01_PerfeCTa_Multiplex_qPCR_0918.indd PCR & qPCR For more info visit: www.quantabio.com PerfeCTa® MultiPlex qPCR ToughMix® FEATURES AND BENEFITS: 1-tube SuperMix minimizes pipetting steps simplifying reaction assembly and improving ac...

MK-SF-0025_REV01_PerfeCTa_Multiplex_qPCR_0918.indd

MK-SF-0025_REV01_PerfeCTa_Multiplex_qPCR_0918.indd PCR & qPCR For more info visit: www.quantabio.com PerfeCTa® MultiPlex qPCR ToughMix® FEATURES AND BENEFITS: 1-tube SuperMix minimizes pipetting steps simplifying reaction assembly and improving ac...

Abundant Protein Depletion of Human Plasma Samples – A Reproducibility and Scaling Study

Abundant Protein Depletion of Human Plasma Samples – A Reproducibility and Scaling Study Sergei I. Snovida1; Katherine E. Herting1; Ramesh Ganapathy1 Ryan Bomgarden1 Barbara J. Kaboord1 Chris Etienne1 John. C. Rogers1 ; Thermo Fisher Scientific Ro...

Abundant Protein Depletion of Human Plasma Samples – A Reproducibility and Scaling Study

Abundant Protein Depletion of Human Plasma Samples – A Reproducibility and Scaling Study Sergei I. Snovida1; Katherine E. Herting1; Ramesh Ganapathy1 Ryan Bomgarden1 Barbara J. Kaboord1 Chris Etienne1 John. C. Rogers1 ; Thermo Fisher Scientific Ro...

ls ge29064295 20131220222354

imagination at work Application note 29-0642-95 AA Chromatography systems Depletion of albumin from serum samples using ÄKTA™ start Albumin comprises 55% to 65% of the total protein in serum. The abundance of this protein makes it difficult to stu...

AP A9019 qPCR Mycoplasma Test Kit

1 qPCR Mycoplasma Test Kit Real time/qPCR test kit for mycoplasma detection Product code A9019___________________________________________________________________________ j Description The Mycoplasma PCR Detection Kit is based on a 5-Nuclease probe...

AP A9019 qPCR Mycoplasma Test Kit

1 qPCR Mycoplasma Test Kit Real time/qPCR test kit for mycoplasma detection Product code A9019___________________________________________________________________________ j Description The Mycoplasma PCR Detection Kit is based on a 5-Nuclease probe...

@@NUMMER 8090145@@

@@NUMMER 8090145@@ 1 DNA-ExitusPlus & DNA-ExitusPlus IF Reagent for the removal of DNA and RNA contaminations Product codes A7089 and A7409 Description DNA-ExitusPlus™ is a novel patented reagent for the removal of nucleic acid contamination fro...

ls ge29064295 20131220222354

imagination at work Application note 29-0642-95 AA Chromatography systems Depletion of albumin from serum samples using ÄKTA™ start Albumin comprises 55% to 65% of the total protein in serum. The abundance of this protein makes it difficult to stu...

@@NUMMER 8090145@@

@@NUMMER 8090145@@ 1 DNA-ExitusPlus & DNA-ExitusPlus IF Reagent for the removal of DNA and RNA contaminations Product codes A7089 and A7409 Description DNA-ExitusPlus™ is a novel patented reagent for the removal of nucleic acid contamination fro...

Chemical_CapabilityTable_v011.indd

Chemical_CapabilityTable_v011.indd For Research Use Only © 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. PFLSPSTORAGECHEM 0716 Chemical Compatibility ...
1 - 16 of 100