Tisk…

Hledali jste: Trubičky pro disperzi plynu

Fritted glass gas tubes are used for introducing gases or liquids into a test tube or flask reaction. The instruments successfully scrub gas in a liquid to saturate or dry gas streams. Gas Tubes with porous glass disc bottom provide a large surface area where the gas and liquid stages meet. Slightly angled models permit precise positioning into flask and eliminate stirring paddle requirement. Tip porosity ranges, outer diameters, and lengths vary to fit desired container.

Fritted glass gas tubes are used for introducing gases or liquids into a test tube or flask reaction. The instruments successfully scrub gas in a liquid to saturate or dry gas streams. Gas Tubes with porous glass disc bottom provide a large surface area where the gas and liquid stages meet. Slightly angled models permit precise positioning into flask and eliminate stirring paddle requirement. Tip porosity ranges, outer diameters, and lengths vary to fit desired container.


46  výsledků nalezeno

SearchResultCount:"46"

Sort Results

Zobrazit seznam Rychlý náhled (novinka)

Ohodnoťte výsledky hledání

Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of carbon dioxide for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.

Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of mercaptan for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.

Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of phosgene for use with an accuro® pump - Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, and air analysis in sewers, shafts and confined spaces.

Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of hydrogen fluoride for use with an Accuro® pump.

Dodavatel: Dräger
Popis: Different gases and vapours can be detected and measured such as concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.

Katalogové číslo: (151-3154)
Dodavatel: Dräger
Popis: <B>Cross sensitivity:</B> Styrene, vinyl acetate, acetaldehyde, acrolein, diesel fuel and furfuryl alcohol are indicated with a yellowish brown discoloration. 500 ppm octane, 5 ppm nitric oxide and 5 ppm nitrogen dioxide have no effect.
Měrná jednotka: 1 * 10 KS


Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of ammonia including determination of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces. For use with an Accuro® pump. Other basic substances such as organic amines are indicated as well. For Ammonia 2/a, 5/a, 5b, the indication is not affected by :
Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of carbon dioxide for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.

Dodavatel: Dräger
Popis: Sampling activated tubes for direct measurement indication even with complex compounds and mixtures of substances in air investigations and gas analyses.

Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of sulphur dioxide for use with an Accuro® pump.
Dodavatel: Dräger
Popis: To measure the 'spot concentrations' of toluene for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, measurement of personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.

Katalogové číslo: (151-0145)
Dodavatel: Dräger
Popis: <B>Operating conditions:</B> 0 to 40 °C ; 3 to 15 mg/l H₂O absolute humidity.
Měrná jednotka: 1 * 10 KS


Dodavatel: Merck
Popis: ORBO™ sorbent tubes contain two beds of the same selective adsorbent seperated by glass wool or foam, for gas and vapor sampling.

Dodavatel: SciLabware
Popis: These Pyrex® borosilicate glass tubes for the dispersion of gas in liquids with sintered thimble allow for the choice of porosities to achieve optimum gas bubble size.

Cena na vyžádání
Omezené množství produktu na skladě. Zboží může být k dispozici v jiném skladě poblíž vašeho sídla. Přesvědčte se, že jste přihlášení na stránky, abyste mohli vidět dostupné položky na skladě. Pokud je stále zobrazeno call a potřebujete asistenci, volejte na číslo 321 570 321.
Omezené množství produktu na skladě. Zboží může být k dispozici v jiném skladě poblíž vašeho sídla. Přesvědčte se, že jste přihlášení na stránky, abyste mohli vidět dostupné položky na skladě. Pokud je stále zobrazeno call a potřebujete asistenci, volejte na číslo 321 570 321.
Daná chemikálie je regulována dle platné legislativy a bude vyžadováno vyplnění formuláře. Jeho včasným vyplněním uspíšíte dodání produktu.
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
Tento produkt je zablokován vaší organizací. Kontaktujte své nákupní oddělení pro více informací.
Původní produkt již není k dispozici. Zobrazen je náhradní produkt.
Tento produkt již není k dispozici. Podobné produkty můžete vyhledat pomocí VWR katalogových čísel nebo čísel dodavatele uvedených výše. Pokud potřebujete další asistenci, zavolejte na telefonní číslo zákaznického servisu VWR 321 570 321.
33 - 46 of 46
no targeter for Bottom